Estación manual direccionable de doble acción, en español, con llave (0600-01570)
Review: 5 -
Rated 5/5 based on 11 customer reviews
"Excelentes productos" by , written onJun 4, 2021
Los productos siempre en tiempo y forma.

Estación manual direccionable de doble acción, en español, con llave (0600-01570)

Disponible: En Stock
$ 2,495.97 MXN
Image

Key Features

  • Bicolor LEDs for alarm and standby
  • Dual action: lift and pull
  • EEPROM programmable address
  • Supports up to 14 AWG wire
  • All-metal construction
Technical Specifications
  • Operating voltage (SLC): 17-41 VDC
  • Average consumption: 550uA (typical), 660uA (alarm)
  • Operating temperature: 0°C to 49°C
  • Maximum humidity: 90% RH non-condensing
  • Dimensions: 86.4mm x 121.9mm x 50.8mm (3.4'W x 4.8'H x 2.0'D)
  • Installation: Single gang or 4' square box
  • Wire gauge: Up to 14 AWG
Available Models
  • DCP-AMS: Single action with hex key
  • DCP-AMS-KL: Single action with key
  • DCP-AMS-LP: Dual action with hex key
  • DCP-AMS-KL-LP: Dual action with key
Standards and Certifications
  • UL Listed
  • CSFM Approved
  • ADA compliant (except LP models)
  • Certification number: 3033215 7150-0410:169

Detailed Description

Hochiki’s DCP-AMS manual stations are addressable alarm stations that provide a quick and convenient means of manually initiating a fire alarm signal. The series includes single and dual action models.

To reset the alarm station, a Cat 30 key or a 1/8' hex key is required (depending on the model). In dual-action models (DCP-AMS-LP and DCP-AMS-KL-LP), the 'Lift and Pull' cover must be lifted before pulling the handle. Once activated, the handle cannot return to its normal position without using the key reset feature.

The DCP-AMS series is electronically addressable and includes a bicolor status LED. The LED flashes green indicating normal communication with the control panel. When an alarm is activated, the LED remains red to indicate the alarm condition.

Installation
  • Designed for mounting in a single gang or 4' square box
  • All-metal construction for durability
  • 'Fire Alarm' text in contrasting color, with 1/2' height
  • Integrated electronics, requires direct connection to the control panel's SLC loop
  • Address programming possible with the station fully installed
Connection Diagrams

Connection to compatible control panel in configuration:

  • Class B (Style 4)
  • Class A (Style 6 & 7)

For correct installation, refer to guide HA-06-135 Rev 12/05


Product Images

DCPAMSKLLPS manual station front DCPAMSKLLPS manual station side

Download the technical sheet here

Key Features

  • Bicolor LEDs for alarm and standby
  • Dual action: lift and pull
  • EEPROM programmable address
  • Supports up to 14 AWG wire
  • All-metal construction
Technical Specifications
  • Operating voltage (SLC): 17-41 VDC
  • Average consumption: 550uA (typical), 660uA (alarm)
  • Operating temperature: 0°C to 49°C
  • Maximum humidity: 90% RH non-condensing
  • Dimensions: 86.4mm x 121.9mm x 50.8mm (3.4'W x 4.8'H x 2.0'D)
  • Installation: Single gang or 4' square box
  • Wire gauge: Up to 14 AWG
Available Models
  • DCP-AMS: Single action with hex key
  • DCP-AMS-KL: Single action with key
  • DCP-AMS-LP: Dual action with hex key
  • DCP-AMS-KL-LP: Dual action with key
Standards and Certifications
  • UL Listed
  • CSFM Approved
  • ADA compliant (except LP models)
  • Certification number: 3033215 7150-0410:169

Detailed Description

Hochiki’s DCP-AMS manual stations are addressable alarm stations that provide a quick and convenient means of manually initiating a fire alarm signal. The series includes single and dual action models.

To reset the alarm station, a Cat 30 key or a 1/8' hex key is required (depending on the model). In dual-action models (DCP-AMS-LP and DCP-AMS-KL-LP), the 'Lift and Pull' cover must be lifted before pulling the handle. Once activated, the handle cannot return to its normal position without using the key reset feature.

The DCP-AMS series is electronically addressable and includes a bicolor status LED. The LED flashes green indicating normal communication with the control panel. When an alarm is activated, the LED remains red to indicate the alarm condition.

Installation
  • Designed for mounting in a single gang or 4' square box
  • All-metal construction for durability
  • 'Fire Alarm' text in contrasting color, with 1/2' height
  • Integrated electronics, requires direct connection to the control panel's SLC loop
  • Address programming possible with the station fully installed
Connection Diagrams

Connection to compatible control panel in configuration:

  • Class B (Style 4)
  • Class A (Style 6 & 7)

For correct installation, refer to guide HA-06-135 Rev 12/05


Product Images

DCPAMSKLLPS manual station front DCPAMSKLLPS manual station side

Download the technical sheet here