Illuminated Call Button with 125 KHz RFID Reader, RS485 BUS, Compatible with NX0019/B, NX0015 and NX1021
- SKU NX0397/R
- Categoria Automatización e Intrusión > Sistemas de Emergencia > Accesorios para Puertas de Emergencia
Description
The NX0397R/G/B module has a button and an integrated RFID reader. The NX0397R model provides a red button to generate alarms, the NX0397G model provides a green button to identify the presence of healthcare personnel and attend to alarms, and the NX0397B model provides a blue button to generate medical alarms and record the presence of medical personnel.
The system notifies different statuses by illuminating each button and with acoustic signals generated by the internal buzzer. The illumination level of the red button on the NX0397R is adjustable, allowing for dim illumination when idle to facilitate locating the button in the dark.
Main Features
- Backlit button
- Acoustic signaling for status notification
- 125kHz RFID reader
- Reading range between 4 and 6 cm
- Power supply 12Vdc
- Communication RS485 bus
- Mounting flush-mounted
Technical Specifications
Operation
The NX0397/R/G/B module is controlled via the RS485 bus, receiving and sending the necessary commands for its operation. Each unit has a unique serial number engraved, which allows it to identify itself within the system.
The RFID reader remains always active, notifying the code of the read RFID cards via the bus. Reading a card takes a maximum of 180ms. If the same card remains within the reader's range, it repeats the read notification every 3 seconds.
The button press status is notified via the RS485 bus. Button illumination and acoustic notification are controlled by messages received via the RS485 bus depending on the application.
The module also uses button illumination to indicate some special statuses:
- Very fast flashing for 2s: Reset
- Slow flashing every 2s: Initialized but not communicating with controller
- Light off: Idle
- Fast flashing every 200ms: Communication with controller lost
- 2 very fast green flashes: RFID read
- Solid red: Firmware update
Installation and Wiring
The NX0397/R/G/B model is mounted in a flush-mount box. It includes a metal frame. Compatible with the NX9003 frame and, through adapters, with several series of electrical equipment from different manufacturers.
The RFID reading range may vary with external factors (interference, nearby metallic elements...). It is recommended to install it, if possible, away from other RFID readers. The RFID reading zone is located in the upper right part of the module's front panel.
Connection to power and to the RS485 bus is made via 4 terminals on the rear:
- 12V: White-orange - Positive power supply
- A: Brown - Data communication
- B: White-brown - Data communication
- GND: Orange - Negative power supply and data communication reference
The module is powered through the 12V and GND signals. If bus power is used, the white-orange and orange wires should be used, respectively. These same terminals can be used to connect the bus power supply. RS485 communication uses the A, B, and GND signals.
For more information, consult the application note on the RS485 bus. All connections must be made with the system disconnected from the power supply.
Description
The NX0397R/G/B module has a button and an integrated RFID reader. The NX0397R model provides a red button to generate alarms, the NX0397G model provides a green button to identify the presence of healthcare personnel and attend to alarms, and the NX0397B model provides a blue button to generate medical alarms and record the presence of medical personnel.
The system notifies different statuses by illuminating each button and with acoustic signals generated by the internal buzzer. The illumination level of the red button on the NX0397R is adjustable, allowing for dim illumination when idle to facilitate locating the button in the dark.
Main Features
- Backlit button
- Acoustic signaling for status notification
- 125kHz RFID reader
- Reading range between 4 and 6 cm
- Power supply 12Vdc
- Communication RS485 bus
- Mounting flush-mounted
Technical Specifications
Operation
The NX0397/R/G/B module is controlled via the RS485 bus, receiving and sending the necessary commands for its operation. Each unit has a unique serial number engraved, which allows it to identify itself within the system.
The RFID reader remains always active, notifying the code of the read RFID cards via the bus. Reading a card takes a maximum of 180ms. If the same card remains within the reader's range, it repeats the read notification every 3 seconds.
The button press status is notified via the RS485 bus. Button illumination and acoustic notification are controlled by messages received via the RS485 bus depending on the application.
The module also uses button illumination to indicate some special statuses:
- Very fast flashing for 2s: Reset
- Slow flashing every 2s: Initialized but not communicating with controller
- Light off: Idle
- Fast flashing every 200ms: Communication with controller lost
- 2 very fast green flashes: RFID read
- Solid red: Firmware update
Installation and Wiring
The NX0397/R/G/B model is mounted in a flush-mount box. It includes a metal frame. Compatible with the NX9003 frame and, through adapters, with several series of electrical equipment from different manufacturers.
The RFID reading range may vary with external factors (interference, nearby metallic elements...). It is recommended to install it, if possible, away from other RFID readers. The RFID reading zone is located in the upper right part of the module's front panel.
Connection to power and to the RS485 bus is made via 4 terminals on the rear:
- 12V: White-orange - Positive power supply
- A: Brown - Data communication
- B: White-brown - Data communication
- GND: Orange - Negative power supply and data communication reference
The module is powered through the 12V and GND signals. If bus power is used, the white-orange and orange wires should be used, respectively. These same terminals can be used to connect the bus power supply. RS485 communication uses the A, B, and GND signals.
For more information, consult the application note on the RS485 bus. All connections must be made with the system disconnected from the power supply.