BOSCH F_FMC420RWGSRRD - Manual Call Point LSN Direccionable / RESET / Surface Mount / Red
- SKU FMC-420RW-GSRRD
- Categoria CCTV Industrial > Incendio > Estaciones Manuales
FMC-420RW-GSRRD Manual Call Point with Reset Option, Red

System summary
FMC-420RW single action alarm call points are used for manual alarm activation and are employed in the local security network (LSN) and the LSN improved version.

Basic functions
Basic functions
Individual identification of the fire alarm call point Neither the single-action call points with glass nor those with a reset option are reset at the fire panel.
The identification of individual fire call points with the display of the call point's address on the fire panel ensures quick location of the activated fire call point.
Planning
- Manual fire call points must be visibly mounted on escape and rescue routes (e.g., exits, corridors, stairwells) and must be easily accessible.
- An installation height of 1400 mm ±200 mm (55 inches, ±8 inches) must be maintained, measured from the center of the call point to the floor.
- The call points must be sufficiently illuminated by sunlight or another light source (including emergency lighting, if available).
- The maximum number of LSN elements that can be mounted depends on their current consumption from the LSN data line. Limit values must be consulted in the product information supplied with the fire panel used.
- Standards, guidelines, and design recommendations regarding the installation location must also be taken into account.
- Local fire department regulations must be followed.
Included parts
- 1 FMC-420RW-GSRRD Fire Alarm Call Point with reset option, surface mount, red.

Features and Specifications
Note: FMC-420RW-GSRRD
Manual fire alarm call point with reset option, red for indoor use, surface mount, direct alarm activation (type A), for LSN improved.
Order number: FMC-420RW-GSRRD.
Main Features
- Alarm activation by pressing the signal or breaking the glass.
- Damage protection with laminated glass and sticker.
- LED indicator for activated alarm or inspection.
- Individual identification of the fire alarm call point.
- Query routines for fire alarm call points with evaluation and multiple transmission.
Specifications
Electrical
- Operating voltage: 15 VDC to 33 VDC.
- Current consumption: 0.4 mA.
Mechanical
Dimensions (H x W x D):
- FMC-420RW-GFRRD 107 mm x 107 mm x 38.5 mm (4.2 in. x 4.2 in. x 1.5 in.)
- Housing material Plastic, ASA Colors.
- Red RAL 3001.
- Blue RAL 5005.
- Yellow RAL 1003.
- Red/white RAL 3001 / RAL 9003.
Environmental
- Protection category according to EN 60529 IP 54.
- Protection category according to EN 60529 for FMC-420RW-HSGRD FMC-420RW-HSRRD IP 67.
- Allowed operating temperature: -25 °C to +70 °C.
- Allowed relative humidity: < 96 %.

Download datasheets/manuals
FMC-420RW-GSRRD Manual Call Point with Reset Option, Red

System summary
FMC-420RW single action alarm call points are used for manual alarm activation and are employed in the local security network (LSN) and the LSN improved version.

Basic functions
Basic functions
Individual identification of the fire alarm call point Neither the single-action call points with glass nor those with a reset option are reset at the fire panel.
The identification of individual fire call points with the display of the call point's address on the fire panel ensures quick location of the activated fire call point.
Planning
- Manual fire call points must be visibly mounted on escape and rescue routes (e.g., exits, corridors, stairwells) and must be easily accessible.
- An installation height of 1400 mm ±200 mm (55 inches, ±8 inches) must be maintained, measured from the center of the call point to the floor.
- The call points must be sufficiently illuminated by sunlight or another light source (including emergency lighting, if available).
- The maximum number of LSN elements that can be mounted depends on their current consumption from the LSN data line. Limit values must be consulted in the product information supplied with the fire panel used.
- Standards, guidelines, and design recommendations regarding the installation location must also be taken into account.
- Local fire department regulations must be followed.
Included parts
- 1 FMC-420RW-GSRRD Fire Alarm Call Point with reset option, surface mount, red.

Features and Specifications
Note: FMC-420RW-GSRRD
Manual fire alarm call point with reset option, red for indoor use, surface mount, direct alarm activation (type A), for LSN improved.
Order number: FMC-420RW-GSRRD.
Main Features
- Alarm activation by pressing the signal or breaking the glass.
- Damage protection with laminated glass and sticker.
- LED indicator for activated alarm or inspection.
- Individual identification of the fire alarm call point.
- Query routines for fire alarm call points with evaluation and multiple transmission.
Specifications
Electrical
- Operating voltage: 15 VDC to 33 VDC.
- Current consumption: 0.4 mA.
Mechanical
Dimensions (H x W x D):
- FMC-420RW-GFRRD 107 mm x 107 mm x 38.5 mm (4.2 in. x 4.2 in. x 1.5 in.)
- Housing material Plastic, ASA Colors.
- Red RAL 3001.
- Blue RAL 5005.
- Yellow RAL 1003.
- Red/white RAL 3001 / RAL 9003.
Environmental
- Protection category according to EN 60529 IP 54.
- Protection category according to EN 60529 for FMC-420RW-HSGRD FMC-420RW-HSRRD IP 67.
- Allowed operating temperature: -25 °C to +70 °C.
- Allowed relative humidity: < 96 %.