{"product_id":"switch-administrable-centrecom-gs970m-capa-3-de-24-puertos-10-100-1000-mbps-4-sfp-gigabit","title":"Switch administrable CentreCOM GS970M, capa 3 de 24 puertos 10\/100\/1000 Mbps + 4 SFP Gigabit","description":"\u003cdiv style=\"width: 100%; max-width: 1200px; margin: 0 auto; font-family: sans-serif; line-height: 1.6; color: inherit; background-color: transparent;\"\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003ePuertos\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e24 puertos 10\/100\/1000 Mbps\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e4 puertos SFP Gigabit\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eVelocidad de reenvío: 41.7 millones de paquetes por segundo (Mpps)\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eCapacidad de conmutación: 56 Gbps\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eSistema Operativo\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eAlliedWare Plus™\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eAdministración\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eInterfaz de línea de comandos (CLI)\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eInterfaz gráfica de usuario (GUI)\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eTelnet\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eSSH\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eMonitoreo SNMP v1, v2c \u0026amp; v3\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eCaracterísticas\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eListas de control de acceso (ACL) basadas en Capa 2, 3 y 4\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eCaracterísticas de IPv6\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eEcológico con el medio ambiente\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eSoporte de autenticación IEEE 802.1x \/ MAC \/ Web\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eSoporte de Multicast - IGMP snooping (IGMPv1, v2 y v3)\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eProtección contra tormentas\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eProtección de unidad de datos de protocolo de puente (BPDU)\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eTri-autenticación\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eQoS (Calidad de Servicio)\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eOcho colas de prioridad\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eLímite de ancho de banda por puerto\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eClasificación de tráfico con baja latencia\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eCaracterísticas de redundancia\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eAnillo conmutado con protección Ethernet (EPSRing)\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eProtección de bucle\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eAgregación de enlaces\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eProtocolo Spanning Tree (STP)\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eProtocolo de árbol de expansión múltiple (MSTP)\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eProtocolo de árbol de expansión rápido (RSTP)\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eFunciones de capa 3 soportadas\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eRuteo estático\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eRIP\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eCaracterísticas físicas y eléctricas\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eAlimentación: 100-240 VCA, 50-60 Hz, 2.4 A\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eDimensiones: Rack de 1U, 44 x 231 x 341 mm\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003ePeso: 2.4 kg\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eTemperatura de operación: 0 a 50° C\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eGarantía\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e1 Año\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8; text-align: center;\"\u003ePanel Frontal del switch GS970M\/28\u003c\/h3\u003e \u003cdiv style=\"text-align: center; margin-top: 15px;\"\u003e \u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150,150,150,0.3); border-radius: 8px;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/adiaz\/AlliedTelesis\/GS970M\/GS970M28.png\" alt=\"Panel Frontal del switch GS970M\/28\"\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003chr style=\"border: 0; border-top: 1px solid rgba(150, 150, 150, 0.3); margin: 30px 0;\"\u003e \u003c\/div\u003e\u003cp\u003e\u003ca href=\"https:\/\/ftp3.syscom.mx\/usuarios\/adiaz\/AlliedTelesis\/GS970M\/gs970m_command_ref_5.4.7-1.x_revb.pdf\" target=\"_blank\"\u003eDescarga la ficha técnica aquí\u003c\/a\u003e\u003c\/p\u003e","brand":"Vigilancianetwork 1","offers":[{"title":"Default Title","offer_id":43069402218562,"sku":"AT-GS970M\/28-10","price":12067.22,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0100\/5276\/3714\/files\/ATGS970M2810-p.png?v=1773068157","url":"https:\/\/www.vigilancianetwork.mx\/es\/products\/switch-administrable-centrecom-gs970m-capa-3-de-24-puertos-10-100-1000-mbps-4-sfp-gigabit","provider":"Vigilancianetwork","version":"1.0","type":"link"}