{"product_id":"fuente-de-poder-dual-altronix-de-12-vcc-9-3-amper-y-24-vcc-9-6-amper-con-16-salidas-con-capacidad-de-bateria-de-respaldo-requiere-bateria-para-aplicaciones-de-control-de-acceso-alarmas-cctv-con-voltaje-de-entrada-en-120-vca","title":"ALTRONIX DUAL Power Supply 12 Vdc @ 9.3 Amp, and 24 Vdc @ 9.6 Amp with 16 outputs, with battery backup capability, requires battery, for access control, alarm, CCTV applications, with 120 Vac input voltage","description":"\u003cdiv style=\"width: 100%; max-width: 1200px; margin: 0 auto; font-family: sans-serif; line-height: 1.6; color: inherit; background-color: transparent;\"\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eDescripción\u003c\/h3\u003e \u003cp style=\"font-size: 15px; color: inherit;\"\u003eLa fuente de poder dual Maximal75F distribuye y conmuta la energía para acceder a sistemas de control y accesorios. Convierte una entrada de 120 VCA 60 Hz en dieciséis (16) salidas de fusible protegidas de 12 VCC y 24 VCC controladas independientemente. Estas salidas de alimentación a prueba de fallas \/ a prueba de seguridad se pueden convertir a contactos 'C' secos. Las salidas se activan mediante un receptor de colector abierto o una entrada de disparo seco normalmente abierto de un sistema de control de acceso, teclado, botón pulsador, REX PIR, etc. Las unidades enrutarán la alimentación a una variedad de dispositivos de hardware de control de acceso, incluidos: cerraduras magnéticas, cerraduras eléctricas, retenedores de puertas magnéticos, etc. La interfaz FACP habilita salidas de emergencia, monitoreo de alarmas o se puede usar para activar otros dispositivos auxiliares. La función de desconexión de alarma contra incendios se puede seleccionar individualmente para una o todas las dieciséis (16) salidas. Todo el equipo de interconexión debe estar listado por UL.\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eEntrada\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eEntrada de 120 VCA 60 Hz, 8.0A.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eOpciones de entrada de fuente de alimentación\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003ea) Dos (2) entradas de alimentación comunes para ACM8 y alimentación de bloqueo (instaladas de fábrica).\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eb) Dos (2) entradas de alimentación aisladas (se requiere una fuente de alimentación externa), (la corriente está determinada por la fuente de alimentación conectada, que no debe exceder un máximo de 10 A en total).\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eDieciséis (16) entradas de activación del sistema de control de acceso.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eOpciones de entrada\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003ea) Dieciséis (16) entradas normalmente abiertas (NO).\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eb) Dieciséis (16) entradas de colector abierto.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003ec) Cualquier combinación de lo anterior.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eSalida\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eSalidas de 12VCC y 24VCC.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eOpciones de salida de corriente máxima:\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eA) 24VCC @ 9.6A más 12VCC @ 9.3A.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eDieciséis (16) salidas controladas independientemente.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eOpciones de salida\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003ea) Dieciséis (16) salidas de potencia a prueba de fallas y\/o a prueba de seguridad.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eb) Dieciséis (16) salidas de relé con clasificación 'C' de 5 A.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003ec) Cualquier combinación de lo anterior.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eDieciséis (16) salidas de alimentación auxiliar (no conmutadas) (las salidas tienen una clasificación de 2.5 A).\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eSalidas filtradas y reguladas electrónicamente (fuente de alimentación incorporada).\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eProtección térmica y contra cortocircuitos con reinicio automático.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eClasificación de fusibles\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eClasificación de fusible de entrada de la fuente de alimentación:\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eeFlow104NB - 6.3A \/ 250V.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eeFlow102NB - 5A \/ 250V.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eEl fusible principal de las tarjetas ACM8 tiene una potencia nominal de 10 A. Las salidas con fusibles tienen una potencia nominal de 3,5 A cada una.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eSupervisión\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eSupervisión de fallas de CA (contactos 'C').\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eEl disparador de notificación se puede seleccionar durante 30 segundos (configurado de fábrica) o 2 horas.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eFallo de batería y supervisión de presencia (contactos 'C').\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eApagado por baja potencia. Apaga los terminales de salida de CC si el voltaje de la batería cae por debajo del 71-73% para unidades de 12V y del 70-75% para unidades de 24V (dependiendo de la fuente de alimentación). Evita la descarga profunda de la batería.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eCaracterísticas\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eLa desconexión de alarma contra incendios (enclavamiento o no enclavamiento) se puede seleccionar individualmente para una o todas las dieciséis (16) salidas.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eOpciones de entrada de desconexión de alarma de incendio:\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003ea) Entrada de contacto seco normalmente abierto (NO) o normalmente cerrado (NC).\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eb) Entrada de inversión de polaridad del circuito de señalización FACP.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eEl relé de salida de alarma indica que se activa la entrada FACP (forma de contacto 'C' con clasificación @ 1A 28VCC).\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eBatería de respaldo\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eCargador incorporado para baterías de plomo-ácido selladas o de gel.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eCambio automático a la batería en espera cuando falla la CA.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eCaída de voltaje cero cuando la unidad cambia a la batería de respaldo (condición de falla de CA).\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eCon capacidad de batería de respaldo.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eNo se incluye batería.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eBaterías sugeridas: PL4.512 \/ PL712 \/ PL912.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eIndicadores visuales\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eLos LED rojos indican que las salidas se disparan (los relés están energizados).\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eEl LED verde indica que se desencadena la desconexión FACP.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eIndicadores LED de entrada de CA y salida de CC.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eTemperatura\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eEn funcionamiento: 0 °C a 49 °C (32 °F a 120 °F).\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eAlmacenamiento: -20 °C a 70 °C (-4 °F a 158 °F).\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eHumedad relativa 85% +\/- 5%.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eBTU\/Hr (aprox.): 177 BTU\/Hr.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eRequisito de VA de entrada de CA del sistema: 960VA.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003chr style=\"border: 0; border-top: 1px solid rgba(150, 150, 150, 0.3); margin: 30px 0;\"\u003e \u003c\/div\u003e\u003cp\u003e\u003ca href=\"http:\/\/ftp3.syscom.mx\/usuarios\/ftp\/2017\/10\/24\/a44d7\/Especificaciones%20t%C3%A9cnicas%20MaximalFDual.pdf\" target=\"_blank\"\u003eDescarga la ficha técnica aquí\u003c\/a\u003e\u003c\/p\u003e","brand":"Vigilancianetwork 1","offers":[{"title":"Default Title","offer_id":43068950184002,"sku":"MAXIMAL75F","price":26430.27,"currency_code":"MXN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0100\/5276\/3714\/files\/MAXIMAL75F-p.png?v=1773065157","url":"https:\/\/www.vigilancianetwork.mx\/es\/products\/fuente-de-poder-dual-altronix-de-12-vcc-9-3-amper-y-24-vcc-9-6-amper-con-16-salidas-con-capacidad-de-bateria-de-respaldo-requiere-bateria-para-aplicaciones-de-control-de-acceso-alarmas-cctv-con-voltaje-de-entrada-en-120-vca","provider":"Vigilancianetwork","version":"1.0","type":"link"}