{"product_id":"estacion-manual-direccionable-de-doble-accion-en-espanol-con-llave-0600-01570","title":"Estación manual direccionable de doble acción, en español, con llave (0600-01570)","description":"\u003cdiv style=\"width: 100%; max-width: 1200px; margin: 0 auto; font-family: sans-serif; line-height: 1.6; color: inherit; background-color: transparent;\"\u003e \u003c!-- Sección de características principales --\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eKey Features\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eBicolor LEDs for alarm and standby\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eDual action: lift and pull\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eEEPROM programmable address\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eSupports up to 14 AWG wire\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eAll-metal construction\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c!-- Sección de especificaciones técnicas --\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eTechnical Specifications\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eOperating voltage (SLC):\u003c\/strong\u003e 17-41 VDC\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eAverage consumption:\u003c\/strong\u003e 550uA (typical), 660uA (alarm)\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e 0°C to 49°C\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eMaximum humidity:\u003c\/strong\u003e 90% RH non-condensing\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 86.4mm x 121.9mm x 50.8mm (3.4'W x 4.8'H x 2.0'D)\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e Single gang or 4' square box\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eWire gauge:\u003c\/strong\u003e Up to 14 AWG\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c!-- Sección de modelos --\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eAvailable Models\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eDCP-AMS: Single action with hex key\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eDCP-AMS-KL: Single action with key\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eDCP-AMS-LP: Dual action with hex key\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eDCP-AMS-KL-LP: Dual action with key\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c!-- Sección de estándares y certificaciones --\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eStandards and Certifications\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eUL Listed\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eCSFM Approved\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eADA compliant (except LP models)\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eCertification number: 3033215 7150-0410:169\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c!-- Sección de descripción detallada --\u003e \u003cdiv style=\"margin-bottom: 30px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eDetailed Description\u003c\/h3\u003e \u003cp style=\"font-size: 15px; color: inherit; margin-bottom: 15px;\"\u003eHochiki’s DCP-AMS manual stations are addressable alarm stations that provide a quick and convenient means of manually initiating a fire alarm signal. The series includes single and dual action models.\u003c\/p\u003e \u003cp style=\"font-size: 15px; color: inherit; margin-bottom: 15px;\"\u003eTo reset the alarm station, a Cat 30 key or a 1\/8' hex key is required (depending on the model). In dual-action models (DCP-AMS-LP and DCP-AMS-KL-LP), the 'Lift and Pull' cover must be lifted before pulling the handle. Once activated, the handle cannot return to its normal position without using the key reset feature.\u003c\/p\u003e \u003cp style=\"font-size: 15px; color: inherit; margin-bottom: 15px;\"\u003eThe DCP-AMS series is electronically addressable and includes a bicolor status LED. The LED flashes green indicating normal communication with the control panel. When an alarm is activated, the LED remains red to indicate the alarm condition.\u003c\/p\u003e \u003c\/div\u003e \u003c!-- Sección de información de instalación --\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eInstallation\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eDesigned for mounting in a single gang or 4' square box\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eAll-metal construction for durability\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e'Fire Alarm' text in contrasting color, with 1\/2' height\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eIntegrated electronics, requires direct connection to the control panel's SLC loop\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eAddress programming possible with the station fully installed\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c!-- Sección de diagramas de conexión --\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eConnection Diagrams\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cp style=\"margin-bottom: 10px; font-size: 14px;\"\u003eConnection to compatible control panel in configuration:\u003c\/p\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eClass B (Style 4)\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eClass A (Style 6 \u0026amp; 7)\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"margin-top: 10px; font-size: 14px;\"\u003eFor correct installation, refer to guide HA-06-135 Rev 12\/05\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c!-- Separador --\u003e \u003chr style=\"border: 0; border-top: 1px solid rgba(150, 150, 150, 0.3); margin: 30px 0;\"\u003e \u003c!-- Sección de imágenes --\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eProduct Images\u003c\/h3\u003e \u003cdiv style=\"display: flex; flex-direction: column; gap: 15px;\"\u003e \u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150,150,150,0.3); border-radius: 8px;\" src=\"http:\/\/ftp3.syscom.mx\/usuarios\/fotos\/DCPAMSKLLPS\/DCPAMSKLLPS_1.png\" alt=\"DCPAMSKLLPS manual station front\"\u003e \u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150,150,150,0.3); border-radius: 8px;\" src=\"http:\/\/ftp3.syscom.mx\/usuarios\/fotos\/DCPAMSKLLPS\/DCPAMSKLLPS_2.png\" alt=\"DCPAMSKLLPS manual station side\"\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c!-- Separador final --\u003e \u003chr style=\"border: 0; border-top: 1px solid rgba(150, 150, 150, 0.3); margin: 30px 0;\"\u003e \u003c\/div\u003e\u003cp\u003e\u003ca href=\"http:\/\/ftp3.syscom.mx\/usuarios\/ftp\/2014\/10\/08\/98b3b\/DCPAMSKLS_Data_Sheet.pdf\" target=\"_blank\"\u003eDownload the technical sheet here\u003c\/a\u003e\u003c\/p\u003e","brand":"Vigilancianetwork 1","offers":[{"title":"Default Title","offer_id":43069034430530,"sku":"DCP-AMS-KL-LP\/S","price":2495.97,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0100\/5276\/3714\/files\/DCPAMSKLLPS-p.png?v=1773065702","url":"https:\/\/www.vigilancianetwork.mx\/es\/products\/estacion-manual-direccionable-de-doble-accion-en-espanol-con-llave-0600-01570","provider":"Vigilancianetwork","version":"1.0","type":"link"}